Critical bug caught in T8 code review: the SW's get_totp handler
gated on core.type === 'login' and referenced core.totp, so the
standalone Totp item type (which lands in T8 with core.type === 'totp'
and core.config) had its detail-view ticker silently rejected with
'no_totp' every second. Ticker swallowed the error; rotating code
display stayed at placeholder forever.
Fix: extend the handler to resolve TotpConfig from either carrier:
- Login items: item.core.totp (optional subfield)
- Totp items: item.core.config (required)
Also:
- Add 3 router tests covering both paths + the empty case
- Remove stale '……' placeholder check in types/totp.ts's \`t\`
keyboard shortcut (dead code — the placeholder is '·····' or
'······', never horizontal ellipses)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>