Adds router_wall_seconds and router_ttft_seconds to energy_observations: - router_wall_seconds: time.monotonic() from just before the accepted candidate's POST/connection-open to the complete response body (buffered) or the last byte forwarded (streaming). Re-marked per candidate so failover time is excluded — a dead model's 30s stall is not charged to the healthy one that replaced it. - router_ttft_seconds: streaming-only. First delta carrying non-empty content or a tool_calls fragment, excluding the role-only opening delta. NULL on buffered rows (not applicable) and on streams that produced no output token (a broken upstream — not the same as a literal 0). Separate from duration_seconds (provider's reported serving time) on purpose: OpenRouter reports duration_seconds on 0 of 3,850 rows, while the router can always measure its own clock. The two quantities are stored independently and never written into each other. log_observation() defaults both new params to None so seed_energy.py and eval_proficiency.py pass unchanged — a reprise of 6e729ad's bug where new keyword-only arguments killed the seed timer. Also: - docs/data-model.md: document the new columns, span definitions, and the distinction from duration_seconds - config/schema.sql: full CREATE TABLE declaration - plans/token-waste-waves.md: status update for Wave 1 - plans/ten-thousand-foot-review.md: companion diagnosis